| Rated Capacity |
70 kilograms (kg) |
| Type |
Strain gauge, full-bridge Wheatstone configuration |
| Output Sensitivity |
Typically 1.0 to 2.0 mV/V at full load |
| Excitation Voltage |
5V to 12V DC (commonly powered at 5V or 10V) |
| Rated Output |
~10 mV signal at 5V excitation when fully loaded |
| Output Resistance |
~350 Ω |
| Input Resistance |
~350 Ω |
| Zero Balance |
±1% of full scale |
| Non-linearity |
≤ ±0.02% F.S. (Full Scale) |
| Hysteresis |
≤ ±0.02% F.S. |
| Repeatability |
≤ ±0.01% F.S. |
| Safe Overload |
Up to 150% of rated capacity |
| Ultimate Overload |
Up to 200% of rated capacity |
| Operating Temperature Range |
–10°C to +50°C |
| Material |
Aluminum alloy (lightweight and corrosion-resistant) |
| Protection Level |
Often IP65 (dust and splash-resistant) |
| Cable Length |
Usually 1 meter, with 4-wire output (Red, Black, Green, White) |
| Mounting Type |
Typically bar-type or half-bridge with mounting holes |
| Recommended Amplifier |
HX711 (24-bit ADC) or INA125 amplifier |